Low Intensity
Infra-Red Tube
Heaters |
|
|

Universal-Ray RH Series Infra-Red Tube heaters
offer more than economy. Quality construction and operational features make
the Universal-Ray system the best in this class of equipment. The RH
Series utilizes direct spark ignition, mirror finished aluminum reflectors
and end caps. Choose from natural or propane gas, 50 to 175 MBTU/H, 20
to 60 foot lengths available in a variety of tube packages and configure
your system as a straight, "U" or "L" shaped heater.
|
Product
Specifications: |
|
Product Features: |
|
BTU/H range: |
50-175 MBTU/H. |
|
-
Enameled control box (light blue).
-
4" combustion air intake collar.
-
Operational indicator lights for
troubleshooting at floor level.
-
Potted circuit board for high moisture
applications.
-
Gas cock and flex connector provided.
-
Single pressure switch operation.
-
Highly polished aluminum reflectors and
end caps.
-
Turbulator baffle for maximum heat
transfer.
-
Totally enclosed components.
|
|
Length: |
20-60 ft. per unit. |
|
|
Warranty: |
1/3/5 (Components/Tubes/Burner) |
|
|
Combustion Tube: |
4"
dia. black coated aluminized or titanium. |
|
|
Radiant Tube(s): |
4"
dia. hot-rolled steel. |
|
|
Electrical: |
120V AC, 60Hz, 3-try spark ignition, 1.7amp startup. |
|
|
|
|
|
|
| |
|
Models |
Gas Type
|
BTU/H
|
Available Tube Lengths |
Recommended Mounting
Heights* |
|
RH 50 |
N
or LP |
50,000 |
20', 30' or 40' |
10' - 16' |
|
RH 75 |
N or LP |
75,000 |
20', 30' or 40' |
13' - 20' |
|
RH 100 |
N
or LP |
100,000 |
30', 40' or 50' |
15' - 23' |
|
RH 125 |
N or LP |
125,000 |
40', 50' or 60' |
15' - 25' |
|
RH 150 |
N
or LP |
150,000 |
40', 50' or 60' |
16' - 30' |
|
RH 175 |
N or LP |
175,00 |
40', 50' or 60' |
17' - 35' |
|
|
* Recommended mounting heights
listed above are provided as a guideline. Actual conditions may
dictate variations from the above data. Always maintain
published clearance to combustibles.
Models are shipped with one 1/2"
gas cock, one 24" stainless steel flex hose, reflector center support,
reflector end caps with clips, turbulator baffle, and applicable clamps and
hangers.
|
| |
|
| |
|
CLEARANCE TO COMBUSTIBLES
(IN.) |
|
CLEARANCE TO COMBUSTIBLES
(IN.) |
|
Model # |
Mounting Angle |
Side |
Top |
Below |
Model # |
Mounting Angle |
Side |
Top |
Below |
|
Front |
Behind |
Front |
Behind |
|
RH 50 |
0º |
9 |
9 |
6 |
47 |
RH 125 |
0º |
20 |
20 |
6 |
76 |
| |
45º |
39 |
8 |
10 |
47 |
|
45º |
58 |
8 |
10 |
76 |
|
w/1 side shield |
0º |
29 |
8 |
6 |
47 |
w/1 side shield |
0º |
42 |
8 |
6 |
76 |
|
w/2 side shields |
0º |
9 |
9 |
6 |
47 |
w/2 side shields |
0º |
20 |
20 |
6 |
76 |
|
20 ft. from burner |
0º |
7 |
7 |
6 |
30 |
20 ft. from burner |
0º |
7 |
7 |
6 |
30 |
|
RH 75 |
0º |
9 |
9 |
6 |
60 |
RH 150 |
0º |
24 |
24 |
6 |
81 |
| |
45º |
39 |
8 |
10 |
60 |
|
45º |
58 |
8 |
10 |
81 |
|
w/1 side shield |
0º |
29 |
8 |
6 |
60 |
w/1 side shield |
0º |
42 |
8 |
6 |
81 |
|
w/2 side shields |
0º |
9 |
9 |
6 |
60 |
w/2 side shields |
0º |
23 |
23 |
6 |
81 |
|
20 ft. from burner |
0º |
7 |
7 |
6 |
30 |
20 ft. from burner |
0º |
11 |
11 |
6 |
44 |
|
RH 100 |
0º |
14 |
14 |
6 |
66 |
RH 175 |
0º |
34 |
34 |
6 |
92 |
| |
45º |
39 |
8 |
10 |
66 |
|
45º |
63 |
8 |
10 |
92 |
|
w/1 side shield |
0º |
29 |
8 |
6 |
66 |
w/1 side shield |
0º |
50 |
8 |
6 |
92 |
|
w/2 side shields |
0º |
16 |
16 |
6 |
66 |
w/2 side shields |
0º |
30 |
30 |
6 |
92 |
|
20 ft. from burner |
0º |
7 |
7 |
6 |
30 |
20 ft. from burner |
0º |
11 |
11 |
6 |
44 |
|
| |
|
|
| |
LITERATURE |
|
| |
Universal-Ray Brochure |
|
| |
RH Series
Installation/Operation Manual |
|
| |
RH Series
Specification Submittal Data Sheet |
|
|
©
2003 Detroit Radiant Products Co. |