Low Intensity
Agricultural Infra-Red
Tube
Heaters |
|
|

Universal-Ray AG Series Infra-Red Tube heaters
offer more than economy. Quality construction and operational features make
the Universal-Ray system the best in this class of equipment. The AG
Series utilizes hot surface ignition, mirror finished aluminum reflectors
and end caps.
|
Product
Specifications: |
|
Product Features: |
|
BTU/H range: |
50-175 MBTU/H. |
|
-
Enameled control box (light blue).
-
4" combustion air intake collar.
-
Operational indicator lights for
troubleshooting at floor level.
-
Potted circuit board for high moisture
applications.
-
Gas cock and flex connector provided.
-
Single pressure switch operation.
-
Highly polished aluminum reflectors and
end caps.
-
Turbulator baffle for maximum heat
transfer.
-
Totally enclosed components.
|
|
Length: |
20-60 ft. per unit. |
|
|
Warranty: |
1/3/5 (Components/Tubes/Burner) |
|
|
Combustion Tube: |
4"
dia. black coated aluminized or titanium. |
|
|
Radiant Tube(s): |
4"
dia. hot-rolled steel. |
|
|
Electrical: |
120V AC, 60Hz, 3-try spark ignition, 1.7amp startup. |
|
|
|
|
|
|
|
|
|
Models |
Gas Type
|
BTU/H
High Fire
|
BTU/H
Low Fire*
|
Applications |
Length |
Recommended
Mtg.
Heights** |
|
Swine |
Arena |
Dairy |
Poultry |
Polebarns & Shops |
|
AG1-20-50 |
N
or LP |
50,000 |
N/A |
No |
Yes |
No |
Yes |
Yes |
21'-7" |
7' - 13' |
|
AG1-20-60 |
N or LP |
60,000 |
N/A |
No |
Yes |
No |
Yes |
Yes |
21'-7" |
7' - 13' |
|
AG2-20-65 |
N or LP |
65,000 |
50,000 |
No |
Yes |
No |
Yes |
Yes |
21'-7" |
7' - 13' |
|
AG1/AG2-20-75 |
N
or LP |
75,000 |
50,000 |
No |
Yes |
Yes |
Yes |
Yes |
21'-7" |
7' - 14' |
|
AG1-30-50 |
N or LP |
50,000 |
N/A |
No |
Yes |
No |
Yes |
Yes |
31'-3" |
7' - 13' |
|
AG1-30-60 |
N
or LP |
60,000 |
N/A |
No |
Yes |
No |
Yes |
Yes |
31'-3" |
7' - 13' |
|
AG2-30-65 |
N or LP |
65,000 |
50,000 |
No |
Yes |
No |
Yes |
Yes |
31'-3" |
7' - 13' |
|
AG1/AG2-30-75 |
N
or LP |
75,000 |
50,000 |
No |
Yes |
Yes |
Yes |
Yes |
31'-3" |
7' - 14' |
|
AG1/AG2-30-100 |
N
or LP |
100,000 |
65,000 |
No |
Yes |
Yes |
Yes |
Yes |
31'-3" |
7' - 14' |
|
AG1-40-60 |
N
or LP |
60,000 |
N/A |
No |
Yes |
No |
Yes |
Yes |
40'-11" |
7' - 13' |
|
AG2-40-65 |
N
or LP |
65,000 |
50,000 |
No |
Yes |
No |
Yes |
Yes |
40'-11" |
7' - 13' |
|
AG1/AG2-40-75 |
N
or LP |
75,000 |
50,000 |
No |
Yes |
Yes |
Yes |
Yes |
40'-11" |
7' - 14' |
|
AG1/AG2-40-100 |
N
or LP |
100,000 |
65,000 |
No |
Yes |
Yes |
Yes |
Yes |
40'-11" |
7' - 14' |
|
AG1/AG2-40-125 |
N
or LP |
125,000 |
95,000 |
No |
Yes |
Yes |
Yes |
Yes |
40'-11" |
7' - 14' |
|
AG1/AG2-40-150 |
N
or LP |
150,000 |
100,000 |
No |
Yes |
Yes |
No |
Yes |
40'-11" |
8' - 16' |
|
AG1/AG2-50-100 |
N
or LP |
100,000 |
65,000 |
No |
Yes |
No |
Yes |
Yes |
50'-7" |
7' - 14' |
|
AG1/AG2-50-150 |
N
or LP |
150,000 |
100,000 |
No |
Yes |
No |
No |
Yes |
50'-7" |
8' - 16' |
|
AG1/AG2-60-125 |
N or LP |
125,000 |
95,000 |
No |
Yes |
No |
No |
Yes |
60'-3" |
9' - 15' |
|
AG1/AG2-60-150 |
N
or LP |
150,000 |
100,000 |
No |
Yes |
No |
No |
Yes |
60'-3" |
9' - 16' |
|
|
|
|
|
* AG2 Series only.
** Recommended mounting heights
listed above are provided as a guideline.
Actual conditions may dictate
variations from the above data.
Always maintain
published clearance to combustibles.
Models are shipped with one 1/2"
gas cock, one 24" stainless steel flex hose, reflector center support,
reflector end caps with clips, turbulator baffle, and applicable clamps and
hangers.
|
| |
|
| |
|
CLEARANCE TO COMBUSTIBLES
(IN.) |
|
CLEARANCE TO COMBUSTIBLES
(IN.) |
|
Model # |
Mtg. Angle |
Side |
Top |
Below |
Model # |
Mtg. Angle |
Side |
Top |
Below |
|
Front |
Behind |
Front |
Behind |
|
AG1 (20,30)-50 |
0º |
9 |
9 |
6 |
47 |
AG1 (30,40,50)-100 |
0º |
14 |
14 |
6 |
66 |
| |
45º |
39 |
8 |
10 |
47 |
|
45º |
39 |
8 |
10 |
66 |
|
w/1 side shield |
0º |
29 |
8 |
6 |
47 |
w/1 side shield |
0º |
29 |
8 |
6 |
66 |
|
w/2 side shields |
0º |
9 |
9 |
6 |
47 |
w/2 side shields |
0º |
16 |
16 |
6 |
66 |
|
20 ft. from burner |
0º |
7 |
7 |
6 |
30 |
20 ft. from burner |
0º |
7 |
7 |
6 |
30 |
|
AG1 (20,30,40)-60 |
0º |
9 |
9 |
6 |
47 |
AG1 40-125 |
0º |
20 |
20 |
6 |
76 |
| |
45º |
39 |
8 |
10 |
47 |
|
45º |
58 |
8 |
10 |
76 |
|
w/1 side shield |
0º |
29 |
8 |
6 |
47 |
w/1 side shield |
0º |
42 |
8 |
6 |
76 |
|
w/2 side shields |
0º |
9 |
9 |
6 |
47 |
w/2 side shields |
0º |
20 |
20 |
6 |
76 |
|
20 ft. from burner |
0º |
7 |
7 |
6 |
30 |
20 ft. from burner |
0º |
7 |
7 |
6 |
30 |
|
AG1 (20,30,40)-75 |
0º |
9 |
9 |
6 |
60 |
AG1 (40,50,60)-150 |
0º |
24 |
24 |
6 |
81 |
| |
45º |
39 |
8 |
10 |
60 |
|
45º |
58 |
8 |
10 |
81 |
|
w/1 side shield |
0º |
29 |
8 |
6 |
60 |
w/1 side shield |
0º |
42 |
8 |
6 |
81 |
|
w/2 side shields |
0º |
9 |
9 |
6 |
60 |
w/2 side shields |
0º |
23 |
23 |
6 |
81 |
|
20 ft. from burner |
0º |
7 |
7 |
6 |
30 |
20 ft. from burner |
0º |
11 |
11 |
6 |
44 |
|
| |
|
|
| |
LITERATURE |
|
| |
Universal-Ray Brochure |
|
| |
AG1
Series IOM
AG1 Series Specifications |
|
| |
AG2
Series IOM
AG2 Series Specifications |
|
| |
|
|
|
©
2004 Detroit Radiant Products Co. |